Fundex Specialist in (deep) foundations
Fundex® Trekanker met Groutinjectie
Vibration-free soil-formed, soil displacement tension anchor, screwed to depth by means of a steel auxiliary tube and under addition of grout injection.
Anchor dimensions:
Standard dimensions are:
| Shaft diameter [mm]: |
Associated drill point [mm]: |
| ø 250 | ø 250 |
Length of anchor:
Up to approximately 30 to 42 meters. The anchor is installed from ground level. This determines the installation length from pile tip level to ground level.
Reinforcement:
Anchors are provided with a central reinforcement bar of one length. The possibility exists to apply a bundle of bars if necessary.
Grout:
The anchors are provided in the work with a grout shell and a central grout core. Various grout compositions can be used in this process.
Soil mechanical bearing capacity:
NL: The bearing capacity is calculated in accordance with current EC, NEN and CUR standards.
B: The bearing capacity is calculated in accordance with current EC, NBN and CUR standards.
Methods:
- A steel auxiliary pipe, equipped with a loose drill point, is placed at ground level;
- The pipe is screwed to depth by applying axial pressure and torque and under the addition of grout injection;
- Upon reaching the desired pile tip level, a central reinforcement rod is inserted into the tube;
- The tube is filled with a grout mixture;
- The tube is pulled, with mixing occurring between the mixed-in-place grout shell and the grout mixture. The drill tip is left behind;
- The anchor is now fabricated;
- The rig can be moved to the next anchor location;
- After excavation, the anchor can be fitted with a head plate which is cast into the structure.
- Vibration-free, and 100% ground displacement (no ground relaxation or reduction in cone resistance)
- No risk of damage to adjoining properties during the manufacture of the pile;
- High tensile load capacity permissible;
- No noise pollution, like pile driving or vibration. Only noise is the drill motor;
- No soil removal. Soil is pushed away laterally.
- Anchor can be installed recessed.
Applicable base:
Fundex tension anchors with grout injection can be well applied in very heavy soil layers.
Inclinations:
Up to 4:1 forward and 2:1 backward.
Working space:
To perform the Fundex tension anchor, one must have a clear height and sufficient space.
Abutments:
The anchors can be installed at a distance of approximately 0.9 m perpendicular to the abutting wall. In the case of recessed corners it is of course more.
Executable rigs:
Fundex F12SE, F15, F2800 and F3500.
Dimensions rigs:
Depends on type rig. Most common;
siding approximately 7 x 12 m. Height rig approximately 35 m.
Built-up weight variable from approximately 63 to 120 tons .
Trekanker, schroevend op diepte gebracht
Installatie Fundex Trekanker
Download PDF:
Fundex Trekanker met Groutinjectie (NL)
Questions or comments?
Please visit our contact page to submit your questions or comments. Our team will contact you as soon as possible. You can also send specific questions directly to the following email addresses:
- Questions about quotes: info@fundex.nl