Fundex Specialist in (deep) foundations
Fundex® Pull Anchor with Grout Injection
Vibration-free, cast-in-place, soil-displacing tension anchor, driven to depth using a steel guide tube and with the addition of grout injection.
Anchor dimensions:
Standard dimensions are:
| Shaft diameter [mm]: |
Recommended drill bit [ ] Drill bit diameter [mm]: |
| ø 250 | ø 250 |
Anchor length:
Approximately 30 to 42 meters. The anchor is installed from ground level. Consequently, the installation length is measured from the tip of the pile to ground level.
Reinforcement:
The anchors are equipped with a single-length central reinforcing bar. It is also possible to use a bundle of bars if necessary.
Grout:
The anchors are provided with a grout shell and a central grout core during installation. Various grout compositions can be used for this purpose.
Soil-bearing capacity:
NL: The bearing capacity is calculated in accordance with current EC, NEN, and CUR standards.
B: The bearing capacity is calculated in accordance with current EC, NBN, and CUR standards.
Procedure:
- A steel guide pipe, fitted with a detachable drill bit, is placed at ground level;
- The pipe is driven to the desired depth by applying axial pressure and torque while injecting grout;
- When the desired pile tip elevation is reached, a central reinforcing bar is placed inside the pipe;
- The pipe is filled with a grout mixture;
- The pipe is pulled out, causing the mixed-in-place grout shell to mix with the grout mixture. The drill bit remains in place;
- The anchor is now complete;
- The rig be moved to the next anchorage;
- After installation, the anchor can be fitted with a head plate that is cast into the structure.
- Vibration-free and 100% soil-displacing (no soil loosening or reduction in cone resistance)
- No risk of damage to adjacent properties during pile construction;
- A high towing capacity is permitted;
- No noise pollution, unlike with pile driving or vibration. The only noise is the drill motor;
- No soil discharge. Soil is pushed out to the side.
- The anchor can be installed at a deeper level.
Suitable soil conditions:
Fundex tension anchors with grout injection are well-suited for use in very heavy soil layers.
Bracing positions:
Up to 4:1 forward and 2:1 backward.
Work area:
Sufficient headroom and space are required for the installation of the Fundex tie rod.
Adjacent walls:
The anchors can be installed at a distance of approximately 0.9 m perpendicular to the adjacent structure. At recessed corners, this distance is naturally greater.
Available rigs:
Fundex F12SE, F15, F2800, and F3500.
Dimensions rigs:
Depends on type rig. Most common;
siding approximately 7 x 12 m. Height rig approximately 35 m.
Built-up weight variable from approximately 63 to 120 tons .
Tension anchor, screwed in place at depth
Installation Fundex Tension Anchor
Download PDF:
Fundex Tension Anchor with Grout Injection (NL)
Questions or comments?
Please visit our contact page to submit your questions or comments. Our team will get back to you as soon as possible. You can also send the following specific questions directly to the email addresses below:
- Questions about quotes: info@fundex.nl
- Questions about job offer: info@werkenbijfundex.nl